Sign in →

EPIC CODE: LAB76 Blood Gas, Arterial

Important Note

replacement test of as 11/16 for test POC185
 

Additional Codes

Sunquest:  ABGS

REGIONAL HOSPITAL PERFORMING

UnityPoint Health Methodist
UnityPoint Health Pekin
UnityPoint Health Proctor

Collect

Collect:  2 mL arterial cord blood in heparinized syringe.  Remove needle, cap syringe tightly.  Gently mix sample well.  Specify O2 therapy.  Patient temperature in Celsius, if indicated. 

Unacceptable Collections:

Uncapped, needle attached, clotted specimen, insufficient quantity, wrong anticoagulant or contaminated or gross hemolysis.

Stability (from collection to initiation)

Stability: (storage/transport temperature)

Immediately at room temperature.  Must be tested within 30 minutes from collection.

Ambient (room temperature)

30 min

Refrigerated 2-8° C

unacceptable

Frozen (-20° C)

Unacceptable

 

 

Storage/Transport Temperature:

Immediately at room temperature.  Must be tested within 30 minutes from collection

Resulting

      Critical
pH 7.35 - 7.45   <7.2 and >7.6
pCO2 35 - 45 mmHg <20 and >70
pO2 80 - 100 mmHg <40
cHCO3 22 -28 mmol/L <10 and >50
Base excess/deficient -3 - 3 mmol/L  
sO2 96-100% %  

 

Ordering

Days Performed:  Sunday - Satuday

Methodology:   Potentiometry

Reported:  Immediately

CPT

82805